DE-207T Digital Multimeter (D.M.M)
Resistance, Diode, Buzzer, Capacitance, Frequency
6000 Counts
-
Measurement Functions:DCV, ACV, DCA, ACA, DCμA, ACμA, DCmA, ACmA, Resistance, Diode, Buzzer, Capacitance, Frequency
- LCD Display:6000 Counts
- Sampling Rate:Approx. 3 Times/Sec.
- Range:Automatic & Manual
- Overload:”OL” Display On LCD
-
Low Battery:
Display On LCD
- Auto Power Off:In 10 Minutes Approx.
- Battery:AA 1.5V x2
- Safety standard:IEC 61010-1 CAT II 1000V IEC 61010-1 CAT.III 600V
Measurement Ranges:
23°C ± 5°C, <80%R.H. Accuracy: ±(%rdg+dgt)
Measurement |
Range |
Resolution |
Accuracy |
Input Resistance |
DC Voltage |
600.0mV |
0.1mV |
0.5%+3 |
Approx. 10MΩ |
6.000V |
0.001V |
|||
60.00V |
0.01V |
|||
600.0V |
0.1V |
0.6%+3 |
||
1000V |
1V |
1.0%+3 |
Measurement |
Range |
Resolution |
Accuracy |
Input Resistance |
|
45~60Hz |
45~400Hz |
||||
AC Voltage |
600.0mV |
0.1mV |
1.0%+10 |
- |
Approx. 10MΩ |
6.000V |
0.001V |
- |
1.0%+5 |
||
60.00V |
0.01V |
||||
600.0V |
0.1V |
1.2%+5 |
|||
1000V |
1V |
1.5%+6 |
Measurement |
Range |
Resolution |
Accuracy |
Max. Input Voltage |
Ω Resistance |
600.0Ω |
0.1Ω |
1.0%+5 |
1000V rms |
6.000kΩ |
0.001kΩ |
|||
60.00kΩ |
0.01kΩ |
|||
600.0kΩ |
0.1kΩ |
|||
6.000MΩ |
0.001MΩ |
2.0%+5 |
||
60.00MΩ |
0.01MΩ |
3.0%+5 |
Measurement |
Range |
Resolution |
Remarks |
Open-loop Voltage |
Max. Input Voltage |
Continuity |
600.0Ω |
0.1Ω |
Buzzer emits at around≦30Ω |
Approx. 0.8V |
1000V rms |
Measurement |
Range |
Resolution |
Accuracy |
Open-loop Voltage |
Max. Input Voltage |
Diode |
2.000V |
0.001V |
1.0%+5 |
Approx. 2.0V |
1000V rms |
* Buzzer emits when signals is around ≦30mV.
Measurement |
Range |
Resolution |
Accuracy |
Remarks |
Max. Input Voltage |
Capacitance |
6.000nF |
0.001nF |
2.0%+20 |
accuracy is subject to the result of the reading deducted the value before applying the test leads to the circuit to be tested (test leads are opened) |
1000V rms |
60.00nF |
0.01nF |
2.0%+5 |
|||
600.0nF |
0.1nF |
||||
6.000μF |
0.001μF |
||||
60.00μF |
0.01μF |
2.5%+5 |
|||
600.0μF |
0.1μF |
||||
6.000mF |
0.001mF |
3.0%+5 |
|||
60.00mF |
0.01mF |
4.0%+5 |
Measurement |
Range |
Resolution |
Accuracy |
Remarks |
|
DC Current |
μA |
660.0μA |
0.1μA |
1.0%+5 |
Protected by a 630mA / 1000V fuse |
μA |
6600μA |
1μA |
|||
mA |
66.00mA |
0.01mA |
|||
mA |
660.0mA |
0.1mA |
|||
A |
10A |
0.01A |
1.6%+6 |
Protected by a 10A / 1000V fuse |
*11 ~ 20A stands with 30 sec. max.
Measurement |
Range |
Resolution |
Accuracy / Response Frequency (DE- 207T at since wave) |
Remarks |
|
45Hz~1kHz |
|||||
AC Current |
μA |
660.0μA |
0.1μA |
1.6%+6 |
Protected by a 630mA / 1000V fuse |
μA |
6600μA |
1μA |
|||
mA |
66.00mA |
0.01mA |
|||
mA |
660.0mA |
0.1mA |
|||
A |
10A |
0.01A |
2.5%+10 |
Protected by a 10A / 1000V fuse |
*11 ~ 20A stands with 30 sec. max.
Measurement |
Range |
Resolution |
Accuracy |
V/Hz |
6.000K/ 60.00K/ 100.0KHz |
0.001K/ 0.01K/ 0.1KHz |
0.1%+3 |
A/Hz |
6.000K/ 60.00K |
0.001K/ 0.01K |
0.1%+3 |
Input Signal |
Minimum Sensitivity of Frequency (RMS sine wave) |
|||
Range |
0.001k - 5.999kHz |
6.00k-20.00kHz |
20.01k-60.00kHz |
60.1k-99.9kHz |
600.0mV |
60mV |
300mV |
- |
- |
6.000V |
0.200V |
0.200V |
1.000V |
3.000V |
60.00V |
1.00V |
1.00V |
2.00V |
5.00V |
600.0V |
10.0V |
10.0V |
20.0V |
30.0V |
1000V |
100V |
100V |
200V |
200V |
600.0μA |
20.0μA |
20.0μA |
20.0μA |
- |
6000μA |
120μA |
200μA |
200μA |
- |
60.00mA |
1.20mA |
2mA |
2mA |
- |
600.0mA |
12.0mA |
20.0mA |
20.0mA |
- |
10A |
1.20A |
1.20A |
1.20A |
- |
TEMP./Humidity:
- Operation:0°C~ 50°C(32℉~122℉)/<80% R.H.(no condensation)
- Storage:-10°C~ 60°C(14℉~140℉)/<70%R.H.(no condensation)
Dimension & Weight:
- 166(L)x96(W)x53(H)mm
- Approx.355g (excluding battery)
Accessories:
-
Battery AA 1.5V x 2
- Instruction Manual x 1
- Test Leads (black + red) x 1
- Built-in auto check measurement signals
- Data hold
- Auto power off selection
- MAX / MIN data hold
- Auto range & manual range
- Overload protection
- None contact voltage detection
- One key shift reading of Hz, A&V