DE-207S Digital Multimeter (D.M.M)

DCV, ACV, DCA, ACA, DCuA, ACuA, DCmA, ACmA
Resistance, DIODE, BUZZER, Capacitance, Frequency, EF
True RMS
6000 Counts
Model : DE-207S(RMS)

  • LCD Display:6000 Counts
  • Sampling Rate:Approx. 3 Times/Sec.
  • Range:Automatic & Manual
  • Overload:”OL” Display On LCD
  • Low Battery:  Display On LCD
  • Auto Power Off:In 10 Minutes Approx.
  • Battery:Standard AA 1.5V x2
  • Safety standard:IEC 61010-1 CAT II 1000V IEC 61010-1 CAT.III 600V


  Measurement Ranges:

23°C ± 5°C, <80%R.H.  Accuracy: ±(%rdg+dgt)

Measurement

Range

Resolution

Accuracy

Input

Resistance

a4.jpg

DC Voltage

600.0mV

0.1mV

0.5%+3

Approx. 10MΩ

6.000V

0.001V

60.00V

0.01V

600.0V

0.1V

0.6%+3

1000V

1V

1.0%+3

 * If reading is <300,accuracy is added 5d on the specified specs (only DE-207S)

Measurement

Range

Resolution

Accuracy

Input

Resistance

45~60Hz

45~400Hz

a3.jpg

AC Voltage

600.0mV

0.1mV

1.0%+10

Approx. 10MΩ

6.000V

0.001V

1.0%+5

60.00V

0.01V

600.0V

0.1V

1.2%+5

1000V

1V

1.5%+6


Measurement

Range

Resolution

Accuracy

Max.

Input Voltage

Ω

Resistance

600.0Ω

0.1Ω

1.0%+5

1000V rms

6.000kΩ

0.001kΩ

60.00kΩ

0.01kΩ

600.0kΩ

0.1kΩ

6.000MΩ

0.001MΩ

2.0%+5

60.00MΩ

0.01MΩ

3.0%+5

 

Measurement

Range

Resolution

Remarks

Open-loop

Voltage

Max.

Input Voltage

a7.jpg

Continuity

600.0Ω

0.1Ω

Buzzer emits at around≦30Ω

Approx. 0.8V

1000V rms

 

Measurement

Range

Resolution

Accuracy

Open-loop

Voltage

Max.

Input Voltage

a6.jpg

Diode

2.000V

0.001V

1.0%+5

Approx. 2.0V

1000V rms

* Buzzer emits when signals is around ≦30mV.

 



Measurement

Range

Resolution

Accuracy

Remarks

Max.

Input Voltage

a5.jpg

Capacitance

6.000nF

0.001nF

2.0%+20

accuracy is subject to the result of the reading deducted the value before applying the test leads to the circuit to be tested (test leads are opened)

1000V rms

60.00nF

0.01nF

2.0%+5

600.0nF

0.1nF

6.000μF

0.001μF

60.00μF

0.01μF

2.5%+5

600.0μF

0.1μF

6.000mF

0.001mF

3.0%+5

60.00mF

0.01mF

4.0%+5

 

Measurement

Range

Resolution

Accuracy

Remarks

DC

Current

μA

660.0μA

0.1μA

1.0%+5

Protected by a 630mA / 1000V fuse

μA

6600μA

1μA

mA

66.00mA

0.01mA

mA

660.0mA

0.1mA

A

10A

0.01A

1.6%+6

Protected by a 10A / 1000V fuse

*11 ~ 20A stands with 30 sec. max.

 

Measurement

Range

Resolution

Accuracy / Response Frequency

(DE- 207T at since wave)

Remarks

45Hz~1kHz

AC

Current

μA

660.0μA

0.1μA

1.6%+6

Protected by a 630mA / 1000V fuse

μA

6600μA

1μA

mA

66.00mA

0.01mA

mA

660.0mA

0.1mA

A

10A

0.01A

2.5%+10

Protected by a 10A / 1000V fuse

*11 ~ 20A stands with 30 sec. max.

 

Measurement

Range

Resolution

Accuracy

V/Hz

6.000K/ 60.00K/ 100.0KHz

0.001K/ 0.01K/ 0.1KHz

0.1%+3

A/Hz

6.000K/ 60.00K

0.001K/ 0.01K

0.1%+3


Input Signal

Minimum Sensitivity of Frequency (RMS sine wave)

Range

0.001k - 5.999kHz

6.00k-20.00kHz

20.01k-60.00kHz

60.1k-99.9kHz

600.0mV

60mV

300mV

6.000V

0.200V

0.200V

1.000V

3.000V

60.00V

1.00V

1.00V

2.00V

5.00V

600.0V

10.0V

10.0V

20.0V

30.0V

1000V

100V

100V

200V

200V

600.0μA

20.0μA

20.0μA

20.0μA

6000μA

120μA

200μA

200μA

60.00mA

1.20mA

2mA

2mA

600.0mA

12.0mA

20.0mA

20.0mA

10A

1.20A

1.20A

1.20A


  TEMP./Humidity:

  • Operation:0°C~ 50°C(32℉~122℉)/<80% R.H.(no condensation)
  • Storage:-10°C~ 60°C(14℉~140℉)/<70%R.H.(no condensation)


  Dimension & Weight:

  • 166(L)x96(W)x53(H)mm
  • Approx.355g (excluding battery)


  Accessories:

  • Battery AA 1.5V x 2
  • Instruction Manual x 1
  • Test Leads (black + red) x 1

  • True RMS
  • Built-in auto check measurement signals
  • Data hold
  • Auto power off selection
  • MAX / MIN data hold
  • Auto range & manual range
  • Overload protection
  • None contact voltage detection
  • One key shift reading of Hz, A&V
  • Backlight