DE-19B Pocket Size Digital Multimeter / Clamp
6600 counts
Max : AC/DC 120A
Measurement Functions:ACA, DCA, ACV, DCV, Resistance, Diode, Buzzer, Capacitance, Frequency, DUTY, REL.
LCD Display:6600 Counts
Sampling Rate:Approx. 3 times per second
Range:Automatic & manual
Overload:”OL” Display On LCD
Low Battery:Display on LCD
Auto Power Off:In 15 Minutes Approx.
Battery:AAA 1.5V x2
Safety standard:IEC 61010-1 CAT II 600V
IEC 61010-1 CAT.III 300V
- Measurement Functions:ACA, DCA, ACV, DCV, Resistance, Diode, Buzzer, Capacitance, Frequency, DUTY, REL.
- LCD Display:6600 Counts
- Sampling Rate:Approx. 3 times per second
- Range:Automatic & manual
- Overload:”OL” Display On LCD
-
Low Battery:
Display on LCD
- Auto Power Off:In 15 Minutes Approx.
- Battery:AAA 1.5V x2
-
Safety standard:IEC 61010-1 CAT II 600V
IEC 61010-1 CAT.III 300V
Measurement Ranges:
23°C ±5°C, 80% R.H. MAX) Accuracy:±(%rdg+dgt)
Measurement |
Range |
Resolution |
Accuracy |
Input Impedance |
Maximum Input Measurement |
Remarks |
(DCA) |
66.00A |
0.01A |
2.0%+10 |
─ |
─ |
─ |
120.0A |
0.1A |
2.0%+5 |
||||
(ACA) |
66.00A |
0.01A |
2.0%+5 (45~400Hz) |
─ |
─ |
─ |
120.0A |
0.1A |
|||||
(DCV)
|
660.0mV |
0.1mV |
1.0%+3 |
Approx. 10MΩ |
─ |
─ |
6.600V |
0.001V |
|||||
66.00V |
0.01V |
|||||
600.0V |
0.1V |
|||||
|
660.0mV |
0.1mV |
1.5%+5 (45~60Hz) |
Approx. 10MΩ |
─ |
─ |
6.600V |
0.001V |
1.5%+5 (45~400Hz) |
||||
66.00V |
0.01V |
|||||
600.0V |
0.1V |
|||||
|
600.0Ω |
0.1Ω |
1.0%+5 |
─ |
600V |
─ |
6.600kΩ |
0.001kΩ |
|||||
66.00kΩ |
0.01kΩ |
|||||
660.0kΩ |
0.1kΩ |
|||||
6.600MΩ |
0.001MΩ |
2.0%+5 |
||||
66.00MΩ |
0.01MΩ |
3.0%+5 |
||||
|
660.0Ω |
0.1Ω |
Buzzer turns on less than 50Ω |
─ |
─ |
Approx. 0.8V |
|
2.000V |
0.001V |
1.0%+5 |
─ |
─ |
Approx. 2.0V |
(Capacitance) |
6.600nF |
0.001nF |
2.5%+5 |
─ |
─ |
6.6nF to 6.6uF ranges. Accuracy is subject to zero set by pressing REL key before forwarding measurement. |
66.00nF |
0.01nF |
|||||
660.0nF |
0.1nF |
|||||
6.600uF |
0.001uF |
|||||
66.00uF |
0.01uF |
|||||
660.0uF |
0.1uF |
|||||
6.600mF |
0.001mF |
3.0%+5 |
||||
66.00mF |
0.01mF |
|||||
V/Hz A/Hz Frequency |
10.0~660.0Hz |
0.1Hz |
0.1%+5 |
─ |
─ |
Value <10.0Hz,the LCD shows 00.0Hz |
6.600kHz |
0.001kHz |
0.1%+3 |
||||
66.00kHz |
0.01kHz |
Sensitivity of Frequency |
||
Signal Range |
Minimum Signals (RMS sine wave) |
|
10Hz~400Hz |
400.1Hz~10.00kHz |
|
660mV |
200mV |
400mV |
6.6V |
0.3V |
0.7V |
66V |
1V |
3V |
660V |
10V |
20V |
66A |
1A |
6A |
120A |
10A |
50A |
Measurement |
Range |
Resolution |
Accuracy |
Remarks |
DUTY |
10%~94.9% |
0.1% |
0.5%+5 |
*No signals or duty cycle is less 10.0%, the LCD shows ”UL”;When duty cycle exceeds 94.9%,the LCD shows OL. *50/60Hz square wave. |
TEMP./Humidity:
- Operation:0°C~ 50°C(32℉~122℉)/<80% R.H.(no condensation)
- Storage:-10°C~ 60°C(14℉~140℉)/<70%R.H.(no condensation)
Dimension & Weight:
- 130(L)x81(W)x22(H)mm
- Approx.160g (Excluding battery)
Accessories:
- Battery AAA 1.5V x2
- Instruction Manual x1
- Max:AC/DC 120A
- Data hold
- Auto power off selection
- Max / Min data hold
- Auto range & manual range
- One touch for fast zero set for DCA
- Overload protection
- One key shift reading of Hz, A & V
- Test leads complied with IEC61010-031 Edition 1.0 2008-02