DE-5203 Digital multimeter

DCV, ACV, DCA, ACA, DCuA, ACuA,DCmA, ACmA, DCmV, ACmV
Resistance, Continuity, Diode, Capacitance, Frequency, Duty, Temperature, REL.
True RMS
22000 counts
Model : DE-5203 (RMS)

  • LCD Display:22000 Counts (main) & bar graph 46 segments
  • Sampling Rate:Approx. 2 times per second
  • Range:Automatic & manual
  • Overload:”OL” Display On LCD
  • Low Battery:  Display on LCD
  • Auto Power Off:In 15 Minutes Approx.
  • Battery:Standard 1.5V x2
  • Safety standard:IEC 61010-1 CAT III 600V ,CAT.II 1000V

  Measurement Ranges:

23°C ± 5°C max. 80%R.H.  Accuracy: ±(%rdg +dgt)

Measurement

Range

Resolution

Accuracy (Responding Hz)

Input

Impedance

Max. Input Voltage

DE-5200

(sine wave)

DE-5202/

5203

a3.jpg

ACV

2.2000V

0.0001V

0.7%+15

(40Hz~1kHz)

*0.7%+40 (40Hz~1kHz)

Approx.

11MΩ

1000V rms

22.000V

0.001V

0.7%+10

(40Hz~1kHz)

*0.8%+40 (40Hz~1kHz)

*1.5%+40

(1kHz~5kHz)

Approx.

10MΩ

220.00V

0.01V

1000.0V

0.1V

1.0%+10

(40Hz~1kHz)

*1.0%+40

(40Hz~2kHz)

*True RMS value: applicable to 10%~100% of the range

Measurement

Range

Resolution

Accuracy

Input

Impedance

Max. Input Voltage

a4.jpg

DCV

2.2000V

0.0001V

0.1%+5

Approx. 11MΩ

1000V rms

22.000V

0.001V

Approx. 10MΩ

220.00V

0.01V

1000.0V

0.1V

0.3%+5

 

Measurement

Range

Resolution

Accuracy

Input

Impedance

Max. Input Voltage

DCmV

220.00mV

0.01mV

0.1%+5

≧100MΩ

1000V rms

 

Measurement

Range

Resolution

Accuracy (Responding Hz)

Input

Impedance

Max. Input Voltage

DE-5200

(sine wave)

DE-5202/

5203

ACmV

220.00mV

0.01mV

0.5%+15

(40Hz~1kHz)

 1.2%+20

(1Hz~2kHz)

*0.5%+30

(40Hz~1kHz)

 *1.2%+30

(1Hz~10kHz)

≧100MΩ

1000V rms

*True RMS value: applicable to 10%~100% of the range

Measurement

Range

Resolution

Accuracy

Overload Protection

Ω

Resistance

220.00 W

0.01W

0.5%+5

1000V rms

2.2000kW

0.0001kW

22.000kW

0.001kW

220.00kW

0.01kW

2.2000MW

0.0001MW

22.000MW

0.001MW

1.0%+10

220.0MW

0.1MW

5.0%+10

 

Measurement

Range

Resolution

Remarks

Open-loop Voltage

Overload Protection

a7.jpg

Continuity

220.00Ω

0.01Ω

Buzzer emits at

around ≦30Ω

-3.0V

1000V rms

 

Measurement

Range

Resolution

Accuracy

Open-loop Voltage

Overload Protection

a6.jpg

Diode

2.2000V

0.0001V

0.5%+5

>2.5V

1000V rms

 

Measurement

Range

Resolution

Accuracy

Open-loop Voltage

Overload Protection

a5.jpg

Capacitance

22.000nF

0.001nF

1.5%+20

At 22nF/220nF ranges

Press “REL” to offset the reading before measurement

1000V rms

220.00nF

0.01nF

2.2000uF

0.0001mF

2.0%+20

22.000mF

0.001mF

220.00mF

0.01mF

2.2000mF

0.0001mF

2.0%+20

22.000mF

0.001mF

220.00mF

0.01mF

6.0%+20

 

Measurement

Range

Resolution

Accuracy

Remarks

Overload Protection

Hz

&

Duty***

22.00Hz*

0.01Hz

0.1%+5

* valid>2.00Hz

** valid > 20.0Hz

***Duty:5%~94.9% (<10kHz3Vp-p) resolution: 0.1%.

Display: UL(<5.0%)

OL (>94.9%)

1000V rms

220.0Hz**

0.1Hz

22.000kHz

0.001kHz

220.00kHz

0.01kHz

 

Measurement

Range

Resolution

Accuracy (Responding Hz)

Overload Protection

DE-5200

(sine wave)

*DE-5202/5203

250mA/ 1000V

fuse

AC

μA

220.00mA

0.01mA

0.8%+10

(40Hz~1kHz)

1.5%+10

(1kHz~2kHz)

*0.8%+30

(40Hz~1kHz)

*1.5%+30

(1kHz~10kHz)

2200.0mA

0.1mA

mA

22.000mA

0.001mA

220.00mA

0.01mA

**A

**10.000A

0.001A

1.8%+20

(40Hz~1kHz)

2.0%+20

(1kHz~2kHz)

*1.5%+30

(40Hz~1kHz)

*2.0%+40

(1kHz~10kHz)

10A/1000V

fuse

over range 11 ~ 20A stands with 30 sec. max.

*True RMS value: applicable to 10% to 100% of the range.

Measurement

Range

Resolution

Accuracy

Overload Protection

DC

μA

220.00mA

0.01mA

0.5%+5

250mA/ 1000V

fuse

2200.0mA

0.1mA

mA

22.000mA

0.001mA

220.00mA

0.01mA

0.8%+5

A

*10.000A

0.001A

1.2%+10

10A/1000V

fuse

over range 11 ~ 20A stands with 30 sec. max.

Measurement

Range

Resolution

Accuracy

DE-5200/5202

DE-5203

°C

°F

-40.0℃~

1000.0℃

-40.0℉~

1830.0℉

0.1℃

0.1℉

 

-40.0℃ ~ 400.0℃

1.0% +4℃

-40.0℉ ~ 752.0℉

1.0% +8℉

400.1℃ ~ 1000.0℃

1.5% +10℃

752.1℉ ~ 1830.0℉

1.5% +18℉

 

Measurement

Range

Accuracy

Remarks

Peak Hold*

DCV, ACV

3.0%+50

* pulse width≧100uS

 

valid≧2000 counts

DCmV, ACmV

DCmA, ACmA

DCmA, ACmA

DCA, ACA

Temperature coefficient: 0.1 x (specified accuracy) / ℃ (<18℃ or >28℃)


  TEMP./Humidity:

  • Operation:0°C~ 50°C(32℉~122℉)/<80% R.H.(no condensation)
  • Storage:-10°C~ 60°C(14℉~140℉)/<70%R.H.(no condensation)

 

  Dimension & Weight:

  • 181(L)x91(W)x57(H)mm
  • Approx.400g (Excluding battery)

 

  Accessories:

  • Battery AAA 1.5V x 2
  • Instruction Manual x 1
  • Test Lead (red + black) x 1


  Optional Accessories:

  • Thermocouple adaptor (NR-38)
  • K type thermocouple (NR-38W)
  • True RMS
  • Bar Graph
  • Peak-max. & Peak-min Hold
  • Max./Min Hold
  • Data Hold
  • Delay Hold
  • Backlight
  • Auto Range & Manual Range
  • Auto Power Off Selection
  • Relative Check
  • AC 3dB Bandwidth LPF
  • HCF Signal Detection
  • Temperature Measurement