DE-5004 Digital Multimeter +LCR

ACV, DCV, ACA, DCA, DCuA, ACuA, DCmA, ACmA
True RMS
Resistance; Frequency; Continuity; Diode; LCR (Inductance Capacitance Resistance)
Intergrate multimeter & L.C.R. function in one meter
Dual display (6000 counts -Main ; 2000 counts-sub. )
Model : DE-5004 (RMS)

  • LCD Display:6600 Counts (main)
                            2000 Counts (sub)
  • Sampling Rate:3 Times/Sec. (DMM mode)
                                 1 Time/Sec. (LCR mode)
  • Range:Automatic & Manual
  • Overload:”OL” Display On LCD
  • Low Battery:   Display On LCD
  • LCR Measurement (auto range)
      *Rs, Rp, Cs, Cp, Ls, Lp, phase angle, Dissipation factor, Quality factor
      *Auto select series or parallel test mode
      *Auto select 100Hz/1kHz/10kHz test frequency, 0.5V rms approx.
      *Calibration
  • Auto Power Off:In 15 Minutes Approx.
  • Battery:1.5V battery x 2
  • Safety standard:IEC 61010-1 CAT III 600V , IEC 61010-1 CAT.II 1000V


  Measurement Ranges:

23°C ± 5°C max. 80%R.H.  Accuracy: ±(%rdg +dgt)

Measurement

Range

Resolution

Accuracy (Responding Hz )

Input Impedance

Max.

Input Voltage

DE-5003

(sine wave)

DE-5004**

(True RMS)

a3.jpg

ACV

6.000V

0.001V

0.7%+6

(40Hz~1kHz)

0.7%+6

(40Hz~1kHz)

2.0%+6

(1kHz~2kHz)


Approx. 11MΩ

1000V rms

60.00V

0.01V

0.7%+5

(40Hz~1kHz)

0.7%+6

(40Hz~1kHz)

2.0%+6

(1kHz~5kHz)

Approx. 10MΩ

600.0V

0.1V

1000V

1V

1.2%+5

(40Hz~1kHz)

1.2%+6

(40Hz~1kHz)

2.0%+6

(1kHz~2kHz)

**True RMS: valid from 10%~100% of range

 

Measurement

Range

Resolution

Accuracy

Input

Impedance

Max.

Input Voltage

DE-5003

DE-5004

a4.jpg

DCV

6.000V

0.001V

0.1%+3

Approx.

11MΩ

1000V rms

60.00V

0.01V

0.2%+3

Approx. 10MΩ

600.0V

0.1V

0.4%+3

1000V

1V

0.6%+5








VA+Hz

( at secondary display)

Accuracy

Max.

Input Voltage

Range

Resolution

DE 5003

DE 5004

600.0Hz

0.1Hz

0.1%+5

1000V rms

6.000KHz

0.001KHz

60.00KHz

0.01KHz






Measurement

ADP

Range

Resolution

Accuracy (Responding Hz )

Input

Impedance

Max.

Input Voltage

DE-5003

(sine wave)

DE-5004**

(True RMS)

ACmV

600.0mV

0.1mV

0.7%+5

(40Hz~2KHz)

0.7%+5*

(40Hz~10KHz)

Approx. 10MΩ

1000V rms

DCmV

600.0mV

0.1mV

0.2%+5

0.2%+5

**True RMS: valid from 10%~100% of range

 

Measurement

Range

Resolution

Accuracy

Max.

Input Voltage

Ω

Resistance

600.0 W *

0.1W

0.5%+5

1000V rms

6.000KW

0.001KW

60.00KW

0.01KW

600.0KW

0.1KW

6.000MW

0.001MW

1.0%+5

60.00MW

0.01MW

2.5%+5

 

Measurement

Range

Resolution

Remarks

Open-loop

Voltage

Max.

Input Voltage

a7.jpg

Continuity

600.0Ω

0.1Ω

Buzzer emits at around ≦10Ω±3Ω

Approx. -3.3V

1000V rms

 

Measurement

Range

Resolution

Accuracy

Open-loop

Voltage

Max.

Input Voltage

a6.jpg

Diode

6.000V

0.001V

0.5%+5

Approx. 2.8V

1000V rms

 

Measurement

Range

Resolution

Accuracy

Remarks

Max.

Input Voltage

Hz

600.0Hz

0.1Hz

0.1%+5

Available reading of Duty:

5.0%~94.9%(<600Hz)

10.0%~90.0%(<6kHz)

20.0%~80.0%(<60kHz)

Resolution 0.1%
Duty smaller than 5%,

The UL will be show on LCD.

Duty larger than 94.9%,

The OL will be show on LCD.

1000V rms

6.000kHz

0.001kHz

60.00kHz

0.01kHz

600.0kHz

0.1kHz

6.000MHz

0.001 MHz

20.00MHz

0.01MHz

 

Measurement

Range

Resolution

Accuracy

Overload

Protection

DC uA

600.0uA

0.1uA

0.5%+5

630mA/1000V fuse

6000uA

1uA

DC mA

60.00mA

0.01mA

600.0mA

0.1mA

DC A

*10.00A

0.01A

1.0%+10

10A/1000V fuse

*overload 11 ~ 20A stands with 30 sec. max.

 

Measurement

Range

Resolution

Accuracy ( Responding Hz)

Overload

Protection

DE-5003

(sine wave)

DE-5004**

(True RMS)

AC uA

600.0uA

0.1uA

1.0%+10

(40Hz~1kHz)

1.5%+10

(1KHz~2KHz)

1.0%+10

(40Hz~1kHz)

1.5%+10

(2KHz~5KHz)

630mA/1000V fuse

6000uA

1uA

AC mA

60.00mA

0.01mA

600.0mA

0.1mA

AC A

*10.00A

0.01A

1.5%+10

(40Hz~2kHz)

1.5%+10

(40Hz~5kHz)

10A/1000V fuse

*over load 11 ~ 20A stands with 30 sec. max.

**True RMS: valid from 10%~100% of range

 

LCR Inductance

Ls/Lp

0.01∼

60.00μH

60.1∼

600.0μH

601∼

6000μH

6.01∼

60.00mH

60.1∼

600.0mH

601∼

6000mH

6.01∼

60.00H

60.1∼

100.0H

 Resolution

0.01μH

0.1μH

1μH

0.01mH

0.1mH

1mH

0.01H

0.1H

Accuracy

±(2.0%+5)

±(1.5%+5)

±(1.0%+5)

±(1.0% +5)

±(1.0%+5)

±(1.0%+5)

±(1.5%+5)

±(2.0%+5)

 

LCR Capacitance

Cs/Cp

0.1∼

600.0pF

601∼

6000pF

6.01∼

60.00nF

60.1∼

600.0nF

601∼

6000nF

6.01∼

60.00μF

60.1∼

600.0μF

0.60∼

6.00mF

 Resolution

0.1pF

1pF

0.01nF

0.1nF

1nF

0.01μF

1μF

0.01mF

Accuracy

±(1.0%+10)

±(0.5%+3)

±(0.3%+3)

±(0.3%+3)

±(0.5%+3)

±(0.8%+3)

±(1.2%+3)

±(2.0%+5)

 

LCR Resistance

Rs/Rp

00.01∼

60.00Ω

60.1∼

600.0Ω

601∼

6000Ω

6.01∼

60.00KΩ

60.1∼

600.0KΩ

601∼

6000KΩ

6.01∼

20.00MΩ

Resolution

0.01Ω

0.01Ω

0.01KΩ

0.1KΩ

1KΩ

0.01MΩ

Accuracy

±(0.5%+5)

±(0.3%+3)

±(0.3%+3)

±(0.3%+3)

±(0.3%+3)

±(1.0%+3)

±(3.0%+5)

 

*Above accuracy is guaranteed after open/short calibration.

*Some types of inductor, the inductance value changes acutely according to the test voltage applied. 

*The meter provides the output voltage around 2.2kΩ / 0.6Vrms at sine wave. However, the test voltage is altered in according to the resistance of the inductor be tested. 

*Temperature coefficient:0.1 x (specified accuracy) / ℃ (from 0℃ to 18℃ or 28℃ to 50℃)


  TEMP./Humidity:

  • Operation:0°C~ 50°C(32℉~122℉)/<80% R.H.(no condensation)
  • Storage:-10°C~ 60°C(14℉~140℉)/<70%R.H.(no condensation)

 

  Dimension & Weight:

  • 181(L)x92(W)x57(H)mm
  • Approx.400g (excluding battery)

 

  Accessories:

  • 1.5V AA Battery x 2
  • Instruction Manual x 1
  • Test Lead (black + red) x 1
  • Test Alligator Clip (red + black) x 1

  • True RMS
  • Integrate Multimeter & L.C.R Function In One Meter
  • Data Hold
  • Dual Display
  • Max./Min Hold
  • Backlight
  • Auto Range & Manual Range
  • Auto Power Off Selection

Related Products