DE-3517 AC/DC Clamp Meter

ACA, DCA, ACV, DCV, Resistance, Buzzer, Diode, Capacitance, Frequency, Duty, REL.
Max. 1000A; Clamp Size ∅40mm
True RMS
Data hold
Auto range & manual range
4000 Count
Model : DE-3517(RMS)

  • Clamp Size:φ40mm or 10x47mm
  • LCD Display:3 3/4 Digits LCD With 4000 Counts
  • Applicable Circuit Voltage:AC 600V or less
  • Sampling Reading Rate:3 Times/ Sec. Approx.
  • Range:Automatic & Manual For Selection
  • Applicable Height:Up to 2000m (above sea level)
  • Auto Power Off:Approx. 30 Minutes
  • Low Battery Display on LCD
  • Battery:AA 1.5V x2
  • Safety standard:IEC 61010-1 , IEC 61010-2-032 600V CAT III Pollution Degree 2


  Measurement Ranges

(23°C ±5°C, 80% R.H. MAX) Accuracy:±(%rdg+dgt)

Measurement

Range

Resolution

AVG Accuracy

True RMS

Accuracy

Input Impedance

Maximum Input Current

Remarks

DE-3516

DE-3517

a1.jpg

(ACA)

400A

0.1A

1.5 %+10

────

1100A

 

1000A

1A

a2.jpg

(DCA)

400A

0.1A

1.5 %+10

────

1100A

 

1000A

1A

a3.jpg

(ACV)

400mV

0.1mV

1.5%+10

≥100MΩ

600V

rms

 

4V

0.001V

approx.

11MΩ

40V

0.01V

approx.

10MΩ

400V

0.1V

1.5%+5

600V

1V

a4.jpg

(DCV)

4V

0.001V

0.7%+3

approx.

11MΩ

600V

 

40V

0.01V

1%+3

approx.

10MΩ

400V

0.1V

600V

1V

oms.gif

(Resistance)

400Ω

0.1Ω

1%+5

────

────

*Open voltage:approx.0.4V

*The measuring current changes in accordance with the resistance measured.

4kΩ

0.001kΩ

40kΩ

0.01kΩ

400kΩ

0.1kΩ

4MΩ

0.001MΩ

3%+5

40MΩ

0.01MΩ

5%+5

a7.jpg

(BUZZER)

400Ω

0.1Ω

────

────

────

The buzzer turns on for resistances below approx.100Ω

a6.jpg

(DIODE)

1.000V

0.001V

10%+5

────

────

Open voltage:

Approx.1.5V

a5.jpg

(CAP)

50nF

0.01nF

3%+10

────

────

Accuracy is subject to zero set by pressing REL. key before forwarding measurement.

500nF

0.1 nF

5μF

0.001μF

50μF

0.01μF

5%+15

100μF

0.1μF

Hz

5.000Hz

0.001Hz

0.7%+5

────

────

*Accuracy in the case of sine wave.

*5.000Hz~100kHz:typical above 5V rms

50.00Hz

0.01Hz

500.0Hz

0.1Hz

5.000kHz

0.001kHz

50.00kHz

0.01kHz

100.0kHz

0.1kHz

DUTY

0.1~99%

0.1%

────

────

────

*About input sensitivity and frequency characteristic:

(Square wave DUTY 50% input) 2.5V 0 to peak input:≧1kHz

6V 0 to peak input:≧10kHz

40V 0 to peak input:≧70kHz

※Remarks:The accuracy data is subject to the conductor to be measured at the center of the iron core (clamp jaw)

 

 

  TEMP./Humidity:

  • Operation:0°C~ 50°C(32~122)/<80% R.H.(no condensation)
  • Storage:-10°C~ 60°C(14~140)/<70%R.H.(no condensation)


  Dimension & Weight:

  • 241(L)x62(W,Max91)x34(H,Max45)mm
  • Approx.410g (Including battery)


  Accessories:

  • Battery AA 1.5V x2
  • Instruction Manual x1
  • Test Lead (black+red) x1
  • Carrying case x1

 

  Optional Accessories:

  • AC Line Splitter(DE-10ALS)
    *Applicable to electrical appliances small current


 


  • True RMS
  • Data Hold
  • Capacitance Measurement
  • Hz/DUTY Measurement
  • Relative Measurement
  • Range Hold
  • Auto Power Off Selection
  • Auto Range & Manual Range
  • One Touch To Zero Set (DCA)
  • High Accuracy

 

Related Products