DE-35 Wireless Clamp Meter (AC/DC)

ACA, DCA, ACV, DCV, Resistance, Buzzer, Diode, Frequency
Patent Design - Multimple Countries
Wireless Transmission of Data - Distance 300 Feet(100M)
Safety & Convenience & Reduce Labor Cost
Simulataneous MAX/MIN Hold with Real Time
Max./Min, Data hold
Audible alarm set for over range
USB interface (optional)
Model : DE-35

  DE-35T (Transmitter)

  • Clamp Size: φ30mm or 10x35mm
  • Auto Range
  • MAX 600A/600V
  • Relative Measurement
  • Auto Power Off Selection
  • Data Hold
  • Sampling Rate: 3 times per second
  • Transmission Time Span: 2, 10, 30, 60 & 120 sec. by user's option


  DE-35R (Receiver – Main Station)

  • Simultaneous MIN /MAX Hold With Real Time
  • Max Hold
  • Data Hold
  • Audible Alarm Set For Over Range at Hi or Lo (Voltage current)
  • Manual Search For Signal
  • 24 Hours Clock.


  Measurement Range

(23°C ±5°C, 80% R.H. MAX) Accuracy:±(%rdg+dgt)

Measurement

Range

Resolution

Accuracy

Input Impedance

Maximum Input Current

Remarks

a1.jpg

(ACA)

400A

0.1A

1.8%+10

────

600A


600A

1A

1%+5

a2.jpg

(DCA)

400A

0.1A

1.8%+10

────

600A


600A

1A

1%+5

a3.jpg
(
ACV)

4V

0.001mV

1.5%+10

Approx.11MΩ

600Vrms


40V

0.01V

Approx.10MΩ

400V

0.1V

1.5%+5

600V

1V

a4.jpg
(
DCV)

400mV

0.1V

0.75%+3

Approx.100MΩ

600V


4V

0.001V

1%+3

Approx.11MΩ

40V

0.01V

Approx.10 MΩ

400V

0.1V

600V

1V

oms.gif
(Resistance)

400Ω

0.1Ω

1%+5

────

600V

*Open circuit voltage:approx.0.4V

*The measuring current changes in accordance with the resistance measured

4kΩ

0.001kΩ

40kΩ

0.01kΩ

400kΩ

0.1kΩ

4MΩ

0.001MΩ

3%+5

40MΩ

0.01MΩ

5%+5

a7.jpg
(
BUZZER)

400Ω

0.1Ω


────

600V

The buzzer turns on for resistances below approx.100Ω

a6.jpg
(
DIODE)

1.000V

0.001V

10%+5

────

600V

Open circuit voltage:

Approx.1.5V

Hz

5.000Hz

0.001Hz

0.7%+5

────

600V

*Accuracy in the case of sine wave.

*5.000Hz~100kHz:typical above 5V rms

50.00Hz

0.01Hz

500.0Hz

0.1Hz

5.000kHz

0.001kHz

50.00kHZ

0.01kHz

100.0kHz

0.1kHz

※The accuracy data for ACA, DCA is subject to the conductor to be measured at the center of the iron core (clamp jaw)



  TEMP./Humidity:

  • Operation:0°C~ 50°C(32℉~122℉)/<80% R.H.(no condensation)
  • Storage:-10°C~ 60°C(14℉~140℉)/<80%R.H.(no condensation)


  Dimension & Weight:

  • DE-35R:179(L)x72(W)x32(H)mm
  • DE-35T:220(L)x64(W)x35(H)mm

 

  Accessories:

  • Battery AA 1.5V x4
  • Instruction Manual x1
  • Test Lead (black+red) x1

 

  Optional Accessories:

  • USB Cable x1
  • CD Rom (software) x1


  • Patent Design – Multiple Countries
  • Measurement Innovation of Clamp Meter
  • Wireless Transmission of Data – Distance 300 feet (100M) at Open Space.
  • Safety & Convenience & Reduce Labor Cost
  • Simultaneous MAX/MIN Hold with Real Time
  • Data Hold, Max Hold
  • 24 hours clock
  • Audible Alarm Function Set at Hi or Lo (voltage or current)
  • Maximum 6 Channels (1 receiver works with 6 transmitters / clamp meter)
  • Variable Built-in Transmission Interval
  • Clamp Meter Operation Individually without Transmission.
  • USB Interface & Software (Optional)
de35-04.jpg