DE-3116 AC/DC Clamp Meter (Pocket Size)

DCV, ACV, DCA, ACA, Resistance, DIODE, BUZZER, Frequency
Max. 600A; Clamp Size ∅30mm
Data hold
Auto range
4000 counts
Model : DE-3116

  • Clamp Size:φ30mm or 10x35mm
  • LCD Display:3 3/4 Digits LCD With 4000 Counts
  • Applicable Circuit Voltage:AC 600V or less
  • Sampling Reading Rate:3 Times/ Sec. Approx.
  • Range:Automatic
  • Applicable Height:Up to 2000m (above sea level)
  • Auto Power Off:Approx. 30 Minutes
  • Low Battery Display on LCD
  • Battery:AA A Battery 1.5V x2
  • Safety standard:IEC 61010-1 , IEC 61010-2-032 600V CAT III Pollution Degree 2


  Measurement Ranges

23°C ±5°C, 80% R.H. MAX) Accuracy:±(%rdg+dgt)

Measurement

Range

Resolution

AVG Accuracy

Input Impedance

Maximum Input Current

Remarks

DE-3116

DE-3116C

a1.jpg

(ACA)

400A

0.1A

1.8%+10

──

600A

 

600A

1A

1%+5

a2.jpg
(DCA)

400A

0.1A

1.8%+10

──

600A


600A

1A

1%+5

a3.jpg
(ACV)

4V

0.001mV

1.5%+10

Approx.

11MΩ

600Vrms

 

40V

0.01V

Approx.

10MΩ

400V

0.1V

1.5%+5

600V

1V

a4.jpg
(DCV)

400mV

0.1V

0.75%+3

Approx.

≥100MΩ

600V

 

4V

0.001V

1%+3

Approx.

11MΩ

40V

0.01V

Approx.

10 MΩ

400V

0.1V

600V

1V

oms.gif
(Resistance)

400Ω

0.1Ω

1%+5

──

600V

*Open circuit voltage:approx.0.4V

*The measuring current changes in accordance with the resistance measured

4kΩ

0.001kΩ

40kΩ

0.01kΩ

400kΩ

0.1kΩ

4MΩ

0.001MΩ

3%+5

40MΩ

0.01MΩ

5%+5

a7.jpg
(BUZZER)

400Ω

0.1Ω


──

600V

The buzzer turns on for resistances below approx.100Ω

a6.jpg
(Diode)

1.000V

0.001V

10%+5

──

600V

Open voltage:approx. 1.5V

a5.jpg

(Capacitance)

50nF

0.01nF

──

3%+10

──

600V

Accuracy is subject to zero set by Pressing REL. key before forwarding measurement.

500nF

0.1nF

5uF

0.001uF

50uF

0.01uF

5%+15

100uF

0.1uF

Hz

5.000Hz

0.001Hz

0.7%+5


──

600V

*Accuracy in the case of sine wave.

*5.000Hz~100kHz:typical above 5V rms

50.00Hz

0.01Hz

500.0Hz

0.1Hz

5.000kHz

0.001kHz

50.00kHZ

0.01kHz

100.0kHz

0.1kHz

※Remarks:The accuracy data for ACA,DCA is subject to the conductor to be measured at the center of the iron core (clamp jaw)


  Temp./Humidity :

  • Operation:0°C~ 50°C(32℉~122℉)/<80% R.H.(no condensation)
  • Storage:-10°C~ 60°C(14℉~140℉)/<70%R.H.(no condensation)

 

  Dimension& Weight :

  • 189(L)x50(W,Max71)x30(H,Max47)mm
  • Approx.220g (Including battery)

 

  Accessories :

  • Battery AAA 1.5V x2
  • Instruction Manual x1
  • Test Leads (red+black) x1
  • Carrying case x1

 

  Optional Accessories:

  • AC Line Splitter(DE-10ALS)
      *Applicable to electrical appliances small current 
  • Auto Range
  • Auto Power Off
  • One touch to zero set (DCA)
  • Data Hold
  • Resolution 0.1A
  • Pocket Size
  • High Accuracy
  • Frequency Measurement