DE-208A Digital Multimeter(D.M.M)

DCV, ACV, DCA, ACA, DCmV, ACmV, DCmA, ACmA, DCuA, ACuA
Resistance, DIODE, BUZZER, Capacitance, Frequency, Temperature, REL. , dBV/dBm, USB
True RMS
6700 Counts
Model : DE-208A(RMS)

  • LCD Display6700 Counts
  • Sampling RateApprox. 4 Times/Sec.
  • RangeAutomatic & Manual
  • Overload:”OL Display On LCD
  • Low Battery Display On LCD
  • Auto Power Off:In 20 Minutes Approx.
  • Battery9V x1
  • Safety standardIEC 61010-1 CAT IV 600V IEC 61010-1 CAT.III 1000V

  Measurement Ranges

23°C ±5°Cmax. 80%R.H.     Accuracy: ±(%rdg +dgt)  *cts=counts

Measurement

Range

Resolution

True RMS Accuracy

OL display

Input Resistance

40Hz ~ 1kHz

1kHz ~ 3kHz

3kHz ~ 10kHz

a3.jpg

ACV

6.700V

0.001V

0.8%+3

1.0%+3

2.0%+3

>6700 counts

Approx

10MΩ/<50pF

67.00V

0.01V

670.0V

0.1V

1000V

1V

1.0%+3

>1050V : OL + beep in urgent sounds + LCD flashing.

*RMS value detection, sine wave

Measurement

Range

Resolution

Accuracy

OL display

Input Resistance

a4.jpg

DCV

6.700V

0.001V

0.09%+2

>6700 counts

Approx.

10MΩ

67.00V

0.01V

670.0V

0.1V

1000V

1V

>1050V: OL + beep in urgent sounds + LCD flashing.


Measurement

Range

Resolution

Accuracy

OL display

Input Resistance

DCmV

67.00mV

0.01mV

0.09%+3

>6700 counts

Approx

10MΩ

670.0mV

0.1V

0.09%+2


Measurement

Range

Resolution

Accuracy

OL display

Input Resistance

40Hz ~ 1kHz

1kHz ~ 3kHz

3kHz ~ 10kHz

ACmV

67.00mV

0.01mV

0.8%+3

1.0%+3

2.0%+3

>6700 counts

Approx

10MΩ

670.0mV

0.1mV

*RMS value detection, sine wave

Measurement

Range

Resolution

Accuracy

OL display

Open Circuit Voltage

Ω

Resistance

670.0Ω

0.1Ω

0.5%+5

>6700 counts

<1.2V

6.700kΩ

0.001kΩ

67.00kΩ

0.01kΩ

670.0kΩ

0.1kΩ

6.700MΩ

0.001MΩ

1.5%+3

67.00MΩ

0.01MΩ

1.8%+3


Measurement

Range

Resolution

Remarks

OL display

Open Circuit Voltage

a7.jpg

Continuity

670.0Ω

0.1Ω

Buzzer < 30Ω±3Ω

>670.0Ω

<1.2V


Measurement

Range

Resolution

Accuracy

OL display

Open Circuit Voltage

a6.jpg

Diode

2.400V

0.001V

1.0%+2

>2400 counts

<2.5V


Measurement

Range

Resolution

Accuracy

OL display

a5.jpg

Capacitance

20.00nF

0.01nF

1.5%+10

>2000 counts

200.0nF

0.1nF

1.2%+5

2.000μF

0.001μF

20.00μF

0.01μF

200.0μF

0.1μF

2.000mF

0.001mF

1.5%+5

30.00mF

0.01mF

2.0%+5

>3000 counts


Measurement

Range

Resolution

Accuracy

OL display

TEMP

°C

-200.0°C ~ 200.0°C

0.1°C

0.5% +1°C

<-200.0°C

>1370°C

200°C ~1370°C

1°C

°F

-328.0 °F ~392.0 °F

0.1°F

0.5% +2°F

<-328.0°C

>2498°F

392 °F ~2498 °F

1°F

Temperature of the interior of meter

(at sub-display)

approx.<-20°C(-4°F)

approx.>70°C(158°F)

-OL display + beep


Measurement

Range

Resolution

Accuracy

OL display

DC

μA

670.0μA

0.1μA

0.2%+5

>6700 counts

6700μA

1μA

mA

67.00mA

0.01mA

670.0mA

0.1mA

A

6.7A

0.001A

0.5%+5

10A

0.01A

>20.1A: OL + beep in urgent sounds + LCD flashing

when measure 11A ~ 20A > 30 sec. beep in continuity


Measurement

Range

Resolution

Accuracy

OL display

40Hz ~ 1kHz

1kHz ~ 3kHz

3kHz ~ 10kHz


AC

μA

670.0μA

0.1μA

0.6%+5

0.8%+5

1.2%+5

>6700 counts

6700μA

1μA

mA

67.00mA

0.01mA

1.0%+5

670.0mA

0.1mA

A

6.7A

0.001A

1.5%+5

10A

0.01A

>20.1A: OL + beep in urgent sounds + LCD flashing

when measure 11A ~ 20A > 30 sec. beep in continuity

* RMS value detection, sine wave

Measurement

Range

Resolution

Accuracy

OL display

Hz

10.0 to 999.9Hz

0.1Hz

0.1%+1

≦300.0kHz

>9999 counts

0.01 to 9.999kHz

0.001kHz

0.01 to 99.99kHz

0.01kHz

0.1kHz to 300kHz

0.1kHz


Measurement

Range

Resolution

Accuracy

OL display

40Hz ~ 1kHz

1kHz ~ 3kHz

3kHz ~ 10kHz

dB V/

dB m

-54~-3dBV

-52~-1dBm

(mV)

0.01dB V/ dB m

0.15dB V/
dB m

(1000V Range)

0.17dB V/ dB m

0.26dB V/ dB m

>6700 counts

(sub-display)

-54~-3dBV

-52~-1dBm

(V)

hen voltage > 1050V, OL + beep in urgent sounds


★Temperature coefficient:

0.1 X (specified accuracy) / °C (<18 °C or >28 °C)

★MAX / MIN

It is added (0.2%+2cts) to the specified accuracy.

Sine wave.

★Peak ±

It is added (1%+30cts) to the specified accuracy, pulse ≧ 0.6msec

Sine wave.


  TEMP./Humidity:

  • Operation:0°C~ 50°C(32℉~122℉)/<80% R.H.(no condensation)
  • Storage:-10°C~ 60°C(14℉~140℉)/<70%R.H.(no condensation)

  Dimension & Weight:

  • 188(L)x95(W)x52(H)mm
  • Approx.415g (excluding battery)

  Accessories:

  • 9V Alkaline Battery x1
  • Instruction Manual x1
  • Test Leads (black + red) x1

 

  Optional Accessories:

  • IR-USB interface adaptor
  • USB cable
  • Software CD ROM
  • Clamp sensor (DE-711)
  • K-TYPE temperature adapter (NR-38)
  • K-TYPE thermocouple (NR-39)

proimages/rimages/DE-208A-Optional.jpg

  • True RMS
  • Auto Hold / Data hold
  • Auto power off selection
  • Auto range & manual range
  • Zero set for capacitance
  • Overload protection with audible alarm
  • Large LCD with dual displays
  • Backlight:Blue
  • Peak+ /Peak-
  • Max / Min / Avg hold with real time
  • Response to AC bandwidth ... max. 10kHz
  • Optional Clamp Sensor:AC/DC 600A max. (DE-711)
  • Bar graph Display
  • Simultaneous display of measuring and meter interior temperature