DE-19B Pocket Size Digital Multimeter / Clamp

ACA, DCA, ACV, DCV, Resistance, DIODE, BUZZER, Capacitance, Frequency, DUTY, REL.
6600 counts
Max : AC/DC 120A
Model : DE-19B

  • LCD Display6600 Counts
  • Sampling RateApprox. 3 times per second
  • RangeAutomatic & manual
  • Overload”OL” Display On LCD
  • Low Battery  Display on LCD
  • Auto Power Off:In 15 Minutes Approx.
  • BatteryStandard 1.5V x2
  • Safety standardIEC 61010-1 CAT II 600V 
                                  IEC 61010-1 CAT.III 300V


  Measurement Ranges

23°C ±5°C, 80% R.H. MAX) Accuracy:±(%rdg+dgt)

Measurement

Range

Resolution

Accuracy

Input Impedance

Maximum Input Current

Remarks

a2.jpg 

(DCA)

66.00A

0.01A

2.0%+10

120.0A

0.1A

2.0%+5

a1.jpg 

(ACA)

66.00A

0.01A

2.0%+5

(45~400Hz)

120.0A

0.1A

a4.jpg

(DCV)

660.0mV

0.1mV

1.0%+3

Approx.

10MΩ

6.600V

0.001V

66.00V

0.01V

600.0V

0.1V

a3.jpg
(ACV)

660.0mV

0.1mV

1.5%+5

(45~60Hz)

Approx.

10MΩ

6.600V

0.001V

1.5%+5

(45~400Hz)

66.00V

0.01V

600.0V

0.1V

oms.gif
(Resistance))

600.0Ω

0.1Ω

1.0%+5

600V

6.600kΩ

0.001kΩ

66.00kΩ

0.01kΩ

660.0kΩ

0.1kΩ

6.600MΩ

0.001MΩ

2.0%+5

66.00MΩ

0.01MΩ

3.0%+5

a7.jpg
(Continuity)

660.0Ω

0.1Ω

Buzzer turns on less than 50Ω

Approx. 0.8V

a6.jpg
(Diode)

2.000V

0.001V

1.0%+5

Approx. 2.0V

a5.jpg

(Capacitance)

6.600nF

0.001nF

2.5%+5

6.6nF to 6.6uF ranges. Accuracy is subject to zero set by pressing REL key before forwarding measurement.

66.00nF

0.01nF

660.0nF

0.1nF

6.600uF

0.001uF

66.00uF

0.01uF

660.0uF

0.1uF

6.600mF

0.001mF

3.0%+5

66.00mF

0.01mF

V/Hz

A/Hz

Frequency

10.0~660.0Hz

0.1Hz

0.1%+5

Value <10.0Hzthe LCD shows 00.0Hz

6.600kHz

0.001kHz

0.1%+3

66.00kHz

0.01kHz

 

Sensitivity of Frequency

Signal Range

Minimum Signals (RMS sine wave)

10Hz~400Hz

400.1Hz~10.00kHz

660mV

200mV

400mV

6.6V

0.3V

0.7V

66V

1V

3V

660V

10V

20V

66A

1A

6A

120A

10A

50A

 

Measurement

Range

Resolution

Accuracy

Remarks

DUTY

10%~94.9%

0.1%

0.5%+5

*No signals or duty cycle is less 10.0%, the LCD shows ”UL”;When duty cycle exceeds 94.9%,the LCD shows OL.

*50/60Hz square wave.

 

  TEMP./Humidity:

  • Operation0°C~ 50°C(32~122)/<80% R.H.(no condensation)
  • Storage-10°C~ 60°C(14~140)/<70%R.H.(no condensation)

 

  Dimension & Weight:

  • 130(L)x81(W)x22(H)mm
  • Approx.160g (Excluding battery)

 

  Accessories:

  • Battery AAA 1.5V x2
  • Instruction Manual x1
  • MaxAC/DC 120A
  • Data hold
  • Auto power off selection
  • Max / Min data hold
  • Auto range & manual range
  • One touch for fast zero set for DCA
  • Overload protection
  • One key shift reading of Hz, A & V
  • Test leads complied with IEC61010-031 Edition 1.0 2008-02