DE-17 Digital Multimeter (Pocket Size)

DCV, ACV, Resistance, DIODE, BUZZER
4300 Counts
Auto Hold; Auto Range
Model : DE-17

  • LCD Display:3¾ digits LCD Display with 4300 Counts
  • Sampling Rate:Approx. 2 Times/Sec.
  • Range:Automatic
  • Overload:”OL” Display On LCD & Beep
  • Low Battery Symbol Display
  • Auto Power Off:In 20 Minutes Approx.
  • Battery:LR-44x2 or SR-44x2
  • Safety standard:IEC 61010-1 CAT. II 600V

  Measurement Ranges

23°C ±5°C, 80% R.H. MAX) Accuracy:±(%rdg+dgt)

Measurement

Range

Resolution

Accuracy

Input Impedance

Maximum Input Voltage

Open-Circuit Voltage

DE-17

a4.jpg

(DCV)

400mV

0.1mV

1.2%+2

>100MΩ

600V


4V

0.001V

0.7%+1

11MΩ

40V

0.01V

1.2%+1

10MΩ

400V

0.1V

600V

1V

a3.jpg

(ACV)

4V

0.001V

2%+5

11MΩ ,<50pF

600V

ms


40V

0.01V

10MΩ ,<50pF

400V

0.1V

600V

1V

oms.gif

(Resistance)

400Ω

0.1Ω

1.2%+2

────

600V

<3.4V

4kΩ

0.001kΩ

<1.0V

40kΩ

0.01kΩ

<0.7V

400kΩ

0.1kΩ

4MΩ

0.001MΩ

2%+3

40MΩ

0.01MΩ

5%+3

a7.jpg

(BUZZER)

400Ω

0.1Ω

The buzzer turns on for resistance lower than 50±20Ω

────

600V

<3.4V

a6.jpg

(DIODE)

2V

0.01V

1.5%+1

────

600V

<3.4V


  TEMP./Humidity:

  • Operation:0°C~ 50°C(32℉~122℉)/<80% R.H.(no condensation)
  • Storage:-10°C~ 60°C(14℉~140℉)/<70%R.H.(no condensation)

  Dimension & Weight:

  • 117(L)x76(W)x18(H)mm
  • Approx.110g (Including battery)

  Accessories:

  • LR-44 Button Cell (installed) x2
  • Instruction Manual x1
  • Test Lead (black + red attached with Meter) x1
  • Pocket Size
  • 4300 Counts LCD Display
  • Auto Hold
  • Auto Range
  • Auto Power Off Selection
  • Low Battery Indication
  • High Accuracy
  • Test Leads Easy To Take Out & Store In