DE-1501 Digital Multimeter

Model : DE-1501

  • LCD Display:2000 Counts 
  • Sampling Rate:Approx. 3 times per second
  • Range: manual
  • Overload:”OL” Display On LCD
  • Low Battery:  Display on LCD
  • Auto Power Off:In 15 Minutes Approx.
  • Battery:Standard 1.5V x2

  Measurement Ranges:

23°C ± 5°C max. 80%R.H.  Accuracy: ±(%rdg +dgt)


Measurement

Range

Resolution

Accuracy

Input Impedance

Max. Input Voltage


DC Voltage

200.0mV

0.1mV

0.3%+3

Approx. 10MΩ

1000V rms

2.000V

0.001V

20.00V

0.01V

200.0V

0.1V

1000V

1V

0.6%+3

 

Measurement

Range

Resolution

Accuracy / Freq. Response

Max. Input Voltage

45- 400Hz

401Hz- 1KHz


AC Voltage

200.0mV

0. 1mV

0.8%+5

0.8%+5

1000V rms

2.000V

0.001V

1.2%+5

20.00V

0.01V

0.8%+5

200.0V

0.1V

1000V

1V

1.0%+5

1.2%+5


Measurement

Range

Resolution

Accuracy

Remark

Max. Input Voltage

Resistance

200Ω

0.1Ω

0.5%+3

l Open circuit :
approx. 0.4V

l Measuring current changes according to the measured resistance value.

600V rms

2kΩ

0.001kΩ

20kΩ

0.01kΩ

200kΩ

0.1kΩ

2MΩ

0.001MΩ

20MΩ

0.01MΩ

1.0%+3

200.0MW

0.1MW

3.0%+5

 

Measurement

Range

Resolution

Remark

Max. Input Voltage

 Continuity

200Ω

0.1Ω

l Bz sounds at less than 30Ω±3Ω

l Open circuit voltage: approx -3.0V

600V rms

 

Measurement

Range

Resolution

Accuracy

Open Circuit Voltage

Max. Input Voltage

 Diode

2.000V

0.001V

1%+3  

Bz sounds at less

than 0.03V

Approx. 2.5V

600V rms

 

Measurement

Range

Resolution

Accuracy

Remark

Max. Input Voltage

Capacitance

2.000nF

0.001nF

1.5%+10

The accuracy of
2.000nF/20.00nF

Is base on reading deducted the residual value of test leads (test leads are opened)

600V rms

20.00nF

0.01nF

1.5%+3

200.0nF

0.1nF

2.000uF

0.001uF

20.00mF

0.01mF

2.5%+3

200.0mF

0.1mF

2.000mF

0.001mF

3.5%+3

20.00mF

0.01mF

 

Measurement

Range

Resolution

Accuracy

Remark

Max. Input Voltage

Hz

200.0Hz

0.1Hz

1.0%+3

Accuracy based on square wave.

600V rms

2.000KHz

0.001KHz

2.000KHz

0.001KHz

20.00KHz

0.01KHz

200.0KHz

0.1KHz

2.000MHz

0.001MHz

20.00MHz

0.01MHz


Measurement

Range

Resolution

Accuracy

Protection Fuse

DC

Current

μA

200.0mA

0.1mA

0.5%+3

FUSE

250mA/ 250V

2000mA

1mA

mA

20.00mA

0.01mA

0.6%+3

200.0mA

0.1mA

10A

10.00A

0.01A

0.6%+3

FUSE 15A/250V

 

Measurement

Range

Resolution

Accuracy / Freq. Response

Protection Fuse

45- 400Hz

401- 1KHz

AC

Current

μA

200.0mA

0.1mA

1.5%+5

FUSE

250mA/ 250V

2000mA

1mA

1.0%+5

mA

20.00mA

0.01mA

1.5%+5

200.0mA

0.1mA

1.0%+5

10A

10.00A

0.01A

1.0%+5

FUSE 15A/250V








Measurement

Range

Resolution

Accuracy

Max. Input Voltage

K-type  ℃/℉

(for DE-1502/1503)

-100℃~1250℃

1℃

1.0% +3℃

600V rms

-148℉~1999℉

1℉

1.0% +5℉


Measurement

Range

Resolution

Measuring range

Remark

NPN

2000

1

The testing value of resistor hFE of NPN type is under 1000

for DE-1501

PNP

2000

1

The testing value of resistor hFE of PNP type is under 1000

 

Function

Range

Remark

NCV

EF

for DE-1503



  TEMP./Humidity:

  • Operation:0°C~ 50°C(32℉~122℉)/<80% R.H.(no condensation)
  • Storage:-10°C~ 60°C(14℉~140℉)/<70%R.H.(no condensation)

 

  Dimension & Weight:

  • 148(L)x76(W)x37(H)mm
  • Approx.170g (Excluding battery)

 

  Accessories:

  • Battery AAA 1.5V x 2
  • Instruction Manual x 1
  • Test Lead (red + black) x 1


  • Large LCD display, easy to read
  • Auto power off & disable Auto power off
  • 0.000nF~20.00mF Capacitance Measurement (Auto Range)
  • 0.0Ω~200.0MΩ Resistance Measurement
  • 0.0Hz~20MHz Frequency Measurement (Auto Range)
  • 0.0 mV~1000V AC/DC Voltage Measurement
  • 0.0μA ~10A AC/DC Current Measurement
  • Hazardous Voltage Indication
  • -100℃~1250℃( -148℉~1999℉)  K-Type Temperature Measurement (1502/ 1503)
  • Not contact AC electric field detection (1503)
  • Transistor hFE test ( 1501)