DE-10 Pocket Size Digital Multimeter

DCV, ACV, Resistance, DIODE, BUZZER
2000 Counts
Auto Range & Manual Range
Data Hold
Model : DE-10

proimages/de10-b.jpg


  • LCD Display:3 1/2 Digits LCD With 2000 Counts
  • Range:Automatic & Manual Range
  • Sampling Rate:Approx. 3 Times/ Sec.
  • Low BatterySymbol Display
  • Auto Power Off:In 15 Minutes Approx.
  • Battery:Li-ion Cell Battery CR2032 (3V) x1
  • Battery Life Time:Approx. 200 Hours At DCV
  • Safety standard:IEC 61010-1 CAT. II 600V Pollution Degree 2

  Measurement Ranges

(23°C ±5°C, 80% R.H. MAX) Accuracy:±(%rdg+dgt)

Measurement

Range

Resolution

Accuracy

Input Resistance

Remarks

DE-10


a3.jpg

(ACV)

2V

0.001V

2.3%+10

approx.

11MΩ

*Accuracy in the case of sine wave.

*Frequency range 40~500Hz

20V

0.01V

approx.

10MΩ

200V

0.1V

2.3%+5

600V

1V

a4.jpg

(DCV)

200mV

0.1mV

0.7%+3

≥100MΩ

────

2V

0.001V

1.3%+3

approx.

11MΩ

20V

0.01V

approx.

10MΩ

200V

0.1V

600V

1V

oms.gif

(Resistance)

200Ω

0.1Ω

2%+5

────

*Openvoltage:approx.0.4V

*The measuring current changes in accordance with the resistance measured.

2kΩ

0.001kΩ

20kΩ

0.01kΩ

200kΩ

0.1kΩ

2MΩ

0.001MΩ

5%+5

20MΩ

0.01MΩ

10%+5

a6.jpg

(DIODE)

2V

0.001V

10%+5

────

Open voltage:Approx.1.5V

a7.jpg

(BUZZER)

200Ω

0.1Ω

────

────

*Buzzer turns on less than 60±20Ω

*Open voltage:Approx. 0.4V


  TEMP./Humidity:

  • Operation:0°C~ 50°C(32~122)/<80% R.H.(no condensation)
  • Storage:-10°C~ 60°C(14~140)/<70%R.H.(no condensation)


  Dimension & Weight:

  • 110(L)x56(W)x11.5(H)mm
  • Approx.96g (Including Battery & Leather Case)


  Accessories:

  • Instruction Manual x 1
  • CR2032 Li-ion Cell (installed) x1
  • Test Lead (black + red attached with Meter) x 1
  • Leather Case x1

  • Super Slim & Light Design
  • Auto Range & Manual Range
  • Auto Power Off Selection
  • MAX Hold
  • Data Hold
  • Leather Case Holder
  • Test Leads Stored Inside-Easy To Carry