DE-3502 AC Clamp Meter

ACA,ACV,DCV,Resistance,Continuity,Frequency,Temperature
Resolution 0.01A
Max. 1000A,Clamp Size ∅40mm
Peak hold/Data hold/Min.&Max.hold
4300 counts
Model : DE-3502

  • Clamp Size:φ40mm or 10x47mm
  • LCD Display:3 3/4 Digits LCD With 4300 Counts
  • Applicable Circuit Voltage:AC 600V or less
  • Sampling Reading Rate:2 Times/ Sec. Approx.
  • Range:Automatic & Manual For Selection
  • Applicable Height:Up to 2000m (above sea level)
  • Auto Power Off:Approx. 10 Minutes
  • Low BatteryDisplay on LCD
  • Battery:AM-3 (LR6) AA Alkaline 1.5V x2
  • Safety standard:IEC 61010-1 , IEC 61010-2-032 600V CAT III Pollution Degree 2


  Measurement Ranges

(23°C ±5°C, 80% R.H. MAX) Accuracy:±(%rdg+dgt)

Measurement

Range

Resolution

AVG Accuracy

Input Impedance

Maximum Input Current

Open-Loop Voltage

DE-3501

DE-3502

a1.jpg

(ACA)

40A

0.01A

1.5 %+8

Peak:2.5% +30

(Response,>1mSec)

────

1100A


400A

0.1A

1.0 %+5

Peak:2% +30

(Response,>1mSec)

1000A

1A

a3.jpg

(ACV)

4V

0.001V

1.0%+5

11MΩ, <50pF

600V

rms


40V

0.01V

10MΩ, <50pF

400V

0.1V

600V

1V

a4.jpg

(DCV)

4V

0.001V

0.75%+2

11MΩ

600V


40V

0.01V

10MΩ

400V

0.1V

600V

1V

oms.gif

(Resistance)

400Ω

0.1Ω

0.9%+2

────

600V

<3.4V

4kΩ

0.001kΩ

<1.0V

40kΩ

0.01kΩ

<0.7V

400kΩ

0.1kΩ

4MΩ

0.001MΩ

2%+2

40MΩ

0.01MΩ

5%+2

a7.jpg

(BUZZER)

400Ω

0.1Ω

The buzzer turns on for sistances lower than 50Ω±25Ω

────

600V

<3.4V

Hz

400Hz

0.1Hz

0.5%+5

────

1100A


4000Hz

1Hz

TEMP

-50°~1100°C

(-58°~2010°F)

1°C /2°F

────

1.0%+5

────

AC 600V

DC 24V


-50°~436.9°C

(-58°~436.9°F)

0.1°C /0.2°F

※Remarks:The accuracy data is subject to the conductor to be measured at the center of the iron core (clamp jaw)


  Temp./Humidity :

  • Operation:0°C~ 50°C(32℉~122℉)/<80% R.H.(no condensation)
  • Storage:-10°C~ 60°C(14℉~140℉)/<70%R.H.(no condensation)

 

  Dimension& Weight :

  • 241(L)x62(W,Max91)x34(H,Max45)mm
  • Approx.390g (Including battery)

 

  Accessories :

  • Battery AM-3 (LR6) AA 1.5V x2
  • Instruction Manual x1
  • Test Lead (black+red) x1
  • Carrying case x1

 

  Optional Accessories :

  • Temperature Probe
  • Temperature Adaptor (NR-38)
  • AC Line Splitter(DE-10ALS)
    *Applicable to electrical appliances small current
  • Resolution 0.01A
  • Peak hold (ACA)
  • Data hold
  • Min. / Max hold (parallel record)
  • Range hold
  • Auto power off selection
  • Auto range & manual range
  • Synchronize measurement of Hz & ACA or ACV
  • High accuracy
  • Temp.