AC Voltage Range
Voltage at 50/60Hz |
ACV 0 ~ 600V |
Accuracy |
Within ±3% of full scale |
Insulation Resistance Ranges
MODEL DE-5010 / DE-5011 / DE-5012
| Model No. |
DE-5010 |
DE-5011 |
DE-5012 |
| Nominal Voltage |
250V
500V
1000V |
125V
250V
500V |
25V
50V
100V |
| Max. Effective Scale Value |
50 MΩ
100MΩ
2000MΩ |
20MΩ
50MΩ
100MΩ |
10MΩ
10MΩ
20MΩ |
| Mid-Scale Value |
1MΩ
2MΩ
50MΩ |
0.5MΩ
1MΩ
2MΩ |
0.2MΩ
0.2MΩ
0.5MΩ |
| Primary Effective Measuring Ranges & Accuracy |
0.05~20 MΩ
0.1~50 MΩ
2~1000 MΩ |
0.02~10MΩ
0.05~20MΩ
0.1~50MΩ |
0.01~5MΩ
0.01~5MΩ
0.02~10MΩ |
| Within ±5% of indicated value |
| Secondary Effective Measuring Ranges & Accuracy |
Scale out of primary effective measuring range (except 0, ∞) |
| Within ±10% of indicated value |
| Accuracy at 0 & ∞ |
Within ±0.7% of scale length from 0 to ∞ |
| Accuracy at no-load voltage |
0%~+20% of nominal voltage |
| Nominal Current |
1mA 0%~+20% |
| Short-circuit Current |
Within 1.5 mA |
* Coarse-line arc on scales indicate the primary effective measuring ranges. (guaranteed accuracy range) |